Precise frequency-difference measurement between the 1.66-μm transitions of methane

Kotaro Suzumura, Chikako Ishibashi, Hiroyuki Sasada

研究成果: Article査読

8 被引用数 (Scopus)

抄録

We determined 66 frequency differences (FD's) between rovibrational lines of methane at the 1.66-μm region. Following the technique developed by Nakagawa et al. [Opt. Lett. 20, 410 (1995)], we measured the FD's as the optical beat frequency between two external-cavity diode lasers locked at 1-MHz-wide saturated absorption dips of the methane lines. Even though the methane lines often overlap in Doppler-limited resolution, the spectrometer that we use resolves them and determines their FD's with better than 40-kHz precision. This fact demonstrates that the methane lines are promising candidates for frequency reference and that this technique has great potential for high-resolution molecular spectroscopy.

本文言語English
ページ(範囲)1356-1358
ページ数3
ジャーナルOptics Letters
22
17
DOI
出版ステータスPublished - 1997 9 1

ASJC Scopus subject areas

  • Atomic and Molecular Physics, and Optics