N2 - This paper describes a large-span structure with a new structural system comprising a semi-rigid (flexible) hanging roof composed of glulams and steel plates. As this roof has low stiffness and small mass, it vibrates and deforms rather easily. Therefore, establishing a rational wind-resistant design is important in evaluating its dynamic response induced by fluctuating wind forces. Geometrical non-linearity must also be considered in evaluating the roof's response. In this study, first, wind-pressure tunnel tests were conducted to investigate the characteristics of fluctuating wind pressures action on the roof. Second, a response analysis taking into account geometrical non-linearity of the roof was carried out using ADINA (Automatic Dynamic Incremental Non-linear Analysis) to evaluate both static and dynamic response induced by static or fluctuating wind force. Finally, a ratio of maximum to mean axial force is proposed as a wind load effect coefficient instead of a gust factor for general buildings.
AB - This paper describes a large-span structure with a new structural system comprising a semi-rigid (flexible) hanging roof composed of glulams and steel plates. As this roof has low stiffness and small mass, it vibrates and deforms rather easily. Therefore, establishing a rational wind-resistant design is important in evaluating its dynamic response induced by fluctuating wind forces. Geometrical non-linearity must also be considered in evaluating the roof's response. In this study, first, wind-pressure tunnel tests were conducted to investigate the characteristics of fluctuating wind pressures action on the roof. Second, a response analysis taking into account geometrical non-linearity of the roof was carried out using ADINA (Automatic Dynamic Incremental Non-linear Analysis) to evaluate both static and dynamic response induced by static or fluctuating wind force. Finally, a ratio of maximum to mean axial force is proposed as a wind load effect coefficient instead of a gust factor for general buildings.
KW - Hanging roof
KW - Non-linear analyses
KW - Wind-induced response
UR - http://www.scopus.com/inward/record.url?scp=0031278079&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0031278079&partnerID=8YFLogxK
U2 - 10.1016/S0167-6105(97)00255-9
DO - 10.1016/S0167-6105(97)00255-9
M3 - Article
AN - SCOPUS:0031278079
VL - 72
SP - 357
EP - 366
JO - Journal of Wind Engineering and Industrial Aerodynamics
JF - Journal of Wind Engineering and Industrial Aerodynamics
SN - 0167-6105
IS - 1-3
ER -