TY - JOUR
T1 - The application of a new stapling device for open surgery (Contour™ Curved Cutter Stapler) in the laparoscopic resection of rectal cancer
AU - Ishii, Y.
AU - Hasegawa, H.
AU - Nishibori, H.
AU - Endo, T.
AU - Kitajima, M.
PY - 2006/8/1
Y1 - 2006/8/1
N2 - Anastomotic leakage is a serious problem in the laparoscopic resection of rectal cancer. Although stapling devices and techniques for colorectal or coloanal anastomosis have been improved, laparoscopic anastomosis is still technically difficult and the rate of leakage is high. To resolve this problem, a new stapling device (the Contour™ Curved Cutter Stapler) for open surgery was applied to the laparoscopic resection of rectal cancer. After intracorporeal mobilization and vessel ligation, a 6-cm Pfannenstiel incision was made to insert the device into the peritoneal cavity, and a hand access device was placed on the site. The head of the device was put through a cutoff of the middle finger of a surgical glove, after which the wrist of the glove was attached to the hand access device. To prevent leakage of CO2 gas through the gap between the shaft and the glove, the shaft covered by the glove was tied, and the gap was filled with bone wax. After re-creation of the pneumoperitoneum, the rectum was transected with the stapling device, and the anastomosis was accomplished by the double stapling technique. This technique enabled a reliable transection of the rectum because of the easy handling of the device and the wide laparoscopic view of the lower rectum in the deep pelvis.
AB - Anastomotic leakage is a serious problem in the laparoscopic resection of rectal cancer. Although stapling devices and techniques for colorectal or coloanal anastomosis have been improved, laparoscopic anastomosis is still technically difficult and the rate of leakage is high. To resolve this problem, a new stapling device (the Contour™ Curved Cutter Stapler) for open surgery was applied to the laparoscopic resection of rectal cancer. After intracorporeal mobilization and vessel ligation, a 6-cm Pfannenstiel incision was made to insert the device into the peritoneal cavity, and a hand access device was placed on the site. The head of the device was put through a cutoff of the middle finger of a surgical glove, after which the wrist of the glove was attached to the hand access device. To prevent leakage of CO2 gas through the gap between the shaft and the glove, the shaft covered by the glove was tied, and the gap was filled with bone wax. After re-creation of the pneumoperitoneum, the rectum was transected with the stapling device, and the anastomosis was accomplished by the double stapling technique. This technique enabled a reliable transection of the rectum because of the easy handling of the device and the wide laparoscopic view of the lower rectum in the deep pelvis.
KW - Curved cutter stapler
KW - Double stapling technique
KW - Laparoscopic resection
KW - Rectal cancer
KW - Surgical glove
UR - http://www.scopus.com/inward/record.url?scp=33747451730&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=33747451730&partnerID=8YFLogxK
U2 - 10.1007/s00464-005-0633-4
DO - 10.1007/s00464-005-0633-4
M3 - Article
C2 - 16763925
AN - SCOPUS:33747451730
VL - 20
SP - 1329
EP - 1331
JO - Surgical Endoscopy and Other Interventional Techniques
JF - Surgical Endoscopy and Other Interventional Techniques
SN - 0930-2794
IS - 8
ER -